<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-04 12-34-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 52 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 3.0 kHz -44 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 18854 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 2,23 dBr 4,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Leila Josefowicz (Viulu), Ac "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.04 12.33.47 Total samples: 18854 Equivalent time: 0:15:42 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,2 dBr MIN: 0,8 dBr AVE: 2,23 dBr % above 12,2 dBr: 0,0 Last value: 1,5 dBr (2026.09.04 12.33.47) 12.20 12.22 12.24 12.26 12.28 12.30 12.32 0 2 4 Pm [dBr]